Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Screw Type Chiller
Created with Pixso. 85HP Industrial Air-Cooled Screw Chiller Energy-Saving Cooling Solution for Extrusion
Detail Information
Place of Origin:
China
Certification:
CE/ISO9001
Product Name:
Air Cooled Screw Chiller
Compressor Control:
0-25-50-75-100%
Expansion Valve:
Emerson
Refrigerant Type:
R22/R407C/R410A/R134A
Air Flow:
60m3/h
Condenser Fan Type:
Air Cooled High-efficient Inner Threaded Copper-tubing Aluminum Fin Type
Cooling Capacity:
85HP
Compressor Brand:
Bitzer/Refcomp/Hanbell
Compressor Quantity:
1
Cooling Method:
Air-cooled
Cooling Type:
Air Cooled Chiller
Type Of Control:
Thermostatic Expansion Valve
Temperature Range:
5℃ ~ 35℃
Highlight:
85HP Industrial Screw Chiller, Air-cooled Screw Chiller For Extrusion, Energy-saving Industrial Cooling Solution
Packaging Details:
Standard export wooden box
Supply Ability:
50 sets/ month
Product Description

Air-cooled screw chiller is a kind of industrial refrigeration and commercial air conditioning equipment, mainly composed of evaporator, compressor, condenser and expansion valve and other components. It uses a screw compressor to compress the low-temperature and low-pressure refrigerant into a high-temperature and high-pressure gas, then releases heat to the outside through the condenser, and finally reduces the temperature and pressure of the refrigerant through the expansion valve to return to the evaporator for recycling.

During operation, the air-cooled screw chiller absorbs the heat in the outdoor air, cools the cooling water and circulates it to the room, so as to reduce the indoor temperature. Its cooling efficiency is greatly affected by factors such as outdoor temperature and humidity, so its effect may be limited in high-temperature and high-humidity environments.

Compared with water-cooled chillers, air-cooled screw chillers do not require an additional cooling water system, so they are simpler and more cost-effective. However, since it uses outside air for cooling, it can be problematic in areas with high air pollution or where indoor air quality needs to be maintained.

Production Features:
  • No additional cooling water system: Compared with water-cooled chillers, air-cooled screw chillers do not require additional cooling water systems, so they are simpler and cost-effective.
  • Wide range of applications: Air-cooled screw chillers are suitable for various types of buildings and places, such as commercial office buildings, hotels, hospitals, schools, etc.
  • High refrigeration efficiency: The air-cooled screw chiller uses a screw compressor, which has the advantages of high refrigeration efficiency, low noise, and low maintenance cost.
  • Easy installation: The installation of the air-cooled screw chiller is relatively simple and does not require additional equipment such as water pipes and water pumps.
  • High reliability: The air-cooled screw chiller is designed and manufactured with high precision, and has good stability and reliability.
  • Strong adaptability: The air-cooled screw chiller has strong adaptability and can adapt to different environmental conditions and load changes.
Working Principle:
  1. Compression process: The refrigerant is compressed into a high-temperature and high-pressure gas in the screw compressor, and then enters the condenser.
  2. Condensation process: The high-temperature and high-pressure gas is cooled in the condenser to become a high-pressure liquid, and at the same time release heat, which is dissipated into the outdoor air through fans and radiators.
  3. Expansion process: After the high-pressure liquid is decompressed by the expansion valve, it becomes a low-temperature and low-pressure liquid, and then enters the evaporator.
  4. Evaporation process: The low-temperature and low-pressure liquid evaporates in the evaporator, absorbs the heat in the room, cools down the cooling water in the room, and circulates it to the room, thereby achieving the purpose of reducing the indoor temperature.
Techinical Parameters:
Model KLA-30A KLA-40A KLA-50A KLA-60A KLA-70A KLA-80A KLA-90A KLA-100A KLA-110A
Cooling capacity KW/h 94.8 126.4 158 189.6 221.2 252.8 284.4 316 347.6
Kcal/h 84,000 112,000 140,000 168,000 196,000 224,000 252,000 280,000 308,000
Temperature range 5℃~35℃(Below 0℃ can be customized)
Power supply 3N-380V/415V 50HZ/60HZ
Total power KW 24.8 33.7 41.5 45.2 57.4 62 69 72.5 83.6
Running current A 41 56.5 69.6 75.9 96.5 86.7 116.2 122 111.3
Chilled water m³/h 15 19.6 24.2 29 35 40 45 50.2 53.8
compressor type Semi-hermetic screw type

Start method Y-△

capacity adjustment 0,25,50,75,100

input power KW 23.3 30.7 38.5 42.2 51.4 56 63 66.3 73
Frozen oil type HBR-A01

filling volume L 7 7 8 12 16 16 16 16 18
refrigerant type R-22/R407C

control method Temperature Sensing External Pressure Equalizing Expansion Valve
Evaporator filling volume KG 16 22 27 32 36 42 46 52 56

type shell and tube
condenser Diameter mm DN65 DN80 DN80 DN80 DN80 DN100 DN100 DN100 DN125

type High-efficiency copper-sleeved aluminum-fin type + low-noise external rotor fan

Cooling air volume m³/h 28000 36000 45000 5500 63000 74000 83000 92000 102000
protective device High and low voltage switch, antifreeze protection, soluble plug, safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Dimensions L mm 2200 2300 2500 2800 2800 2910 3100 3150 3150

W mm 1100 1100 1200 1200 1800 2050 2050 2050 2050

H mm 1820 2030 2030 2030 2100 2100 2100 2100 2100
weight KG 920 1120 1350 1560 1780 1920 2230 2450 2720
Model KLA-120D KLA-130A KLA-150A KLA-160D KLA-180D KLA-200D KLA-240D KLA-260D KLA-300D
Cooling capacity KW/h 379.2 410.8 474 505.6 568.8 632 758.4 821.6 948
Kcal/h 336,000 364,000 420,000 448,000 504,000 560,000 672,000 728,000 840,000
Temperature range 5℃~35℃(Below 0℃ can be customized)
Power supply 3N-380V/415V 50HZ/60HZ
Total power KW 149 169 195.1 204.8 240 247.5 282 309.4 364.5
Running current A 88.6 100.5 114.8 120.5 141.6 145.6 165.5 182 214.4
Chilled water m³/h 59 65 74 79 90 101 119 130 152
compressor type Semi-hermetic screw type

Start method Y-△

capacity adjustment 0,25,50,75,100

input power KW 79.6 88.5 102.8 108.5 126.6 130.6 150.5 167 199.4
Frozen oil type HBR-A01

filling volume L 18 18 23 24 24 28 32 32 36
refrigerant type R-22/R407C

control method Temperature Sensing External Pressure Equalizing Expansion Valve
Evaporator filling volume KG 62 66 75 80 92 103 121 126 150

type shell and tube
condenser Diameter mm DN1250 DN150 DN200

type High-efficiency copper-sleeved aluminum-fin type + low-noise external rotor fan

Cooling air volume m³/h 112000 122000 141000 150000 169000 189000 223000 245000 285000
protective device High and low voltage switch, antifreeze protection, soluble plug, safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Dimensions L mm 3500 3800 4120 4250 4680 4680 5230 5630 6550

W mm 2100 2100 2100 2100 2100 2100 2100 2100 2210

H mm 2120 2120 2120 2120 2120 2120 2120 2120 2150
weight KG 3050 3360 3670 3550 4120 4230 4650 5570 7420
Application Industry:
  • Commercial office buildings: Commercial office buildings usually require a large amount of air-conditioning equipment to maintain a comfortable indoor environment, and air-cooled screw chillers can meet these needs.
  • Hotel and tourism industry: The hotel and tourism industry usually require large-scale air conditioning systems to provide a comfortable accommodation environment, and air-cooled screw chillers can meet these needs.
  • Hospitals and medical institutions: Hospitals and medical institutions need to maintain a constant temperature and humidity to ensure the normal operation of the equipment and the comfort of the patients, and the air-cooled screw chiller can provide these services.
  • Industrial manufacturing: Industrial manufacturing usually requires large-scale refrigeration equipment to maintain the normal operation of production lines and equipment, and air-cooled screw chillers can meet these needs.
  • Shopping malls and supermarkets: Shopping malls and supermarkets need large-scale air-conditioning systems to provide a comfortable shopping environment, and air-cooled screw chillers can provide these services.

In short, It is widely used in pharmaceutical, chemical, food, grease, coating, electroplating, cold storage, plastic, chemical fiber, commercial concrete, laser, purification workshop, mechanical processing and other industries. It can precisely control the temperature required by modern industrial manufacturing, greatly improving efficiency and product quality. JIALIS chiller is easy to operate, reasonable in design and superior in quality, with more than 100 models, it is the best choice for modern industrial refrigeration.

KLA-100A Air Cooled Screw Chiller , Industrial Water Chillers CE ISO Standard 1 KLA-100A Air Cooled Screw Chiller , Industrial Water Chillers CE ISO Standard 2 KLA-100A Air Cooled Screw Chiller , Industrial Water Chillers CE ISO Standard 3 KLA-100A Air Cooled Screw Chiller , Industrial Water Chillers CE ISO Standard 4

85HP Industrial Air-Cooled Screw Chiller Energy-Saving Cooling Solution for Extrusion 0
Upport and Services:
  • 24/7 customer support
  • Remote guidance installation and maintenance
  • Remote Diagnostics and Troubleshooting
  • Phone/Email Advice and Guidance
  • User friendly documentation and manuals
  • Software Updates and Upgrades
  • Cost price of spare parts and consumables
Packing and Shipping:

Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.

Maintenance Method:
  1. Clean filters and coils regularly: Clean filters and coils regularly to avoid clogging with dust and grime that can affect cooling performance.
  2. Check the electrical system: Regularly check the electrical system, including wires, plugs, and switches, to make sure it is functioning properly.
  3. Clean the condenser and evaporator: Clean the condenser and evaporator regularly to maintain good heat dissipation and cooling effects.
  4. Check the refrigerant: Regularly check the pressure and concentration of the refrigerant to make sure it is at normal levels.
  5. Check the screw compressor: Regularly check the operation of the screw compressor, including noise, vibration and oil level, etc,to ensure its normal operation.
  6. Check the motor and fan: Periodically check the operation of the motor and fan to make sure they are functioning properly.
  7. Check the plumbing system: Regularly check the tightness and leakage of the plumbing system to ensure its normal operation.

In short, regular maintenance and maintenance can ensure the normal operation and prolong the service life of the air-cooled screw chiller. It is recommended to carry out care and maintenance according to the manufacturer's recommendations, and regularly ask professional maintenance personnel for maintenance and inspection.